通化硕抠家具有限公司

    鋼管超聲波測厚示值減小的原因分析

    Analysis of Causes for Ultrasonic Gauge-measured Steel Pipe Thickness Value's being Less than Real value

    • 摘要: 在使用超聲波測厚儀對鋼管壁厚進(jìn)行測量時,有時會出現(xiàn)示值小于鋼管實(shí)際壁厚的情況,并且這些鋼管內(nèi)表面往往伴有許多鼓包和翹皮出現(xiàn)。對這種情況進(jìn)行了分類統(tǒng)計(jì),并取樣進(jìn)行分析。指出鋼管超聲波測厚示值減小是由分布在壁厚中間和靠近內(nèi)表面區(qū)域的異常夾雜物引起的,內(nèi)表面的鼓包和翹皮是由分布在壁厚靠近內(nèi)表面邊緣區(qū)域的異常夾雜物引起的;鋼管內(nèi)表面的翹皮與二輥斜軋穿孔變形產(chǎn)生的毛管內(nèi)折有本質(zhì)的區(qū)別。

       

      Abstract: When using an ultrasonic thickness gauge to measure the steel pipe,sometimes the indication values resulting from the testing are less than the real ones,and in such cases,the pipes being measured are always found to have inner bulges and fins.Classified statistics and sample analysis are made to such cases.As a result,it is identified that the problem concerning smaller indication values is caused by the nonmetallic inclusions as distributed in the middle wall area and the area close to the inner surface of the pipe,while the bulges and fins of the pipe are caused by the nonmetallic inclusions as held in the area just under the inner surface thereof.The said inner fin of the pipe is substantially different from the inner fold of the shell as occurring due to the deformation produced by the 2-roll rotary piercing process.

       

    /

    返回文章